Home | » Products | » Vacuum Drying Oven | » Air Quality Sensor |
Digital output dust concentration signal output unit μg/m3;
Built-in microprocessor MCU optimized precise algorithm; standard serial port output;
Digital PWM pulse width output and standard serial port (USART);
Built-in software self-calibration function, simple debugging, high efficiency and accuracy, good consistency;
Light particle counting principle, digital output, simple application, universal interface;
high sensitivity can detect particles with a diameter of 1μm or more;
Compact structure, light weight (W48.1xH17XD32.3 mm), embedded installation;
Using active air flow structure, real-time data characteristics;
Dual air inlet structure, suitable for more design, convenient installation;
SY210 is a laser optical refractometer that detects the number of dust particles in the air and has an embedded MCU
Digital dust sensor for digital detection of real-time environment dust concentration by outputting directly from the operating system and outputting data
Unit μg/m3. Intersecting the laser light source with the optical axis of an image sensor when dusty airflow
Reflected light is generated through the intersection area. The image sensor detects dust reflected laser light, according to precision
High-speed op amp amplification and internal modulation circuit and MCU count and algorithm, operation system particle number and weight conversion,
Direct output of digital signals of dust concentration, this sensor can sensitively detect particles with a diameter of 1.0μm or more,
Repeatedly optimized and precise data processing through the built-in microprocessor MCU has greatly improved the accuracy.
Directly output PM2.5 concentration signal in the current environment, unit μg/m3
Air purifier, air refresher
Air dust detection, indoor air dust quality detection;
Home appliances, air conditioners, HVAC, new fans,
Ventilation system, smoke alarm or other dust monitoring equipment detection components
As non-metering instrument detection components (Note: This product does not require high reliability, safety, precision
Equipment and measuring instrument components);
No. | Parameter | Specifications |
1 | Supply voltage | DC5V±5% ( CN1:Pin1=GND, Pin2=+5V ) |
2 | Power Consumption | 50mA ± 10% |
3 | Working temperature and humidity | â10~55°C, 95% RH or less (without condensation) |
4 | Storage temperature | -30°C~60°C |
5 | Detection particle diameter | 1μm or more |
6 | Detection of dust particle concentration range | 5~990μg/m3 (PWM output mode) |
7 | signal output | PWM output in μg/m3/USART serial outputOutput level: LOW=0V, HI=4.0V |
8 | dimensions | W48 .1x H17 x D32.3 (mm) |
9 | weight | about 30g |
10 | Measurement start time | Approx. 1 minute after power on (system internal correction time) |